RadiSys ATCA-4616 Specifikace Strana 28

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 146
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 27
2
Software Architecture
28
•UsingthefrontpanelresetbuttontoresettheactiveSCMeithermanuallyorusingHPI
withthesaHPIResourceResetStateSet()function.
WhentheSCMisactingastheactiveShelfManager,itsActiveLEDglowsamber.Onthe
standbyShelfManager,thisLEDflashesperiodically,aboutonceevery2seconds.Duringa
switchoveroperationinwhichtherolesoftheShelfManagersareswapped,theLEDflashes
rapidlyonthe ShelfManagerthatismovingfromstandbymodetoactivemodeuntilthe
switchoveriscomplete.ArapidlyflashingamberLEDindicatesthattheShelfManageris
preparingitshighavailabilityrole.AfterashelfpoweruporanSCMreboot,youmightseethe
amberLEDflashingrapidlybeforeitbecomessteadyinactivemodeorslowlyblinkingin
standbymode.
Shelf Manager redundancy sensor
TheHPIShelfManagerresourcecontainsastandardsensorthatmonitorstheShelf
Managersredundancystatus.TheShelfManagerredundancysensorisadiscretesensorthat
indicatesiftheShelfManagerisredundantatanypointoftime.Fordescriptions,seethe
virtualShelfManagerresourceRPTentrysectionoftheSAFMappingSpecification.
TheShelfManagersareconsideredredundantwhenthefollowingconditionsaremet:
1. TheactiveShelfManagerhasestablishedthepresenceofthestandbyShelfManager
usingadedicatedIPMIoveraLANsessionoverthesynchronizationchannel.
2. ThestandbyHPIserverhassuccessfullycompletedtheinitialrefreshsyncwiththeactive
HPIserver.
3. TheactiveandstandbyShelfManagershaveestablishedthattheyarerunningthesame
softwareversion.
Whenalloftheaboveconditionsaremet,theShelfManagerredundancysensorreportsthe
eventstateSAHPI_ES_FULLY_REDUNDANT,signifyingfullredundancyhasbeenachieved.
Ifthefirsttwoconditionsare
notmet,theShelfManagerredundancysensorreportsthe
eventstateSAHPI_ES_REDUNDANCY_LOST_SUFFICIENT_RESOURCES,signifyingthatthe
ShelfManagersarecurrentlynotredundant,buttheactiveShelfManagerisstillcapableof
managingtheshelf.Associatedalarmsarecreat edwhenredundancyislostbetweentheShelf
Managers.
Ifthethirdconditionisnotmet,theShelfManagerredundancysensorreportstheeventstate
SAHPI_ES_REDUNDANCY_DEGRADED,signifyingthattheShelfManagerisstillfully
functional,butthatanynewfeaturesavailablewiththelatersoftwareversionaredisabled.
Thisconditionisnotconsideredanalarmandnoalarmislogged;however,aneventis
generated.
Zobrazit stránku 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 145 146

Komentáře k této Příručce

Žádné komentáře