RadiSys EPC-2 Specifikace Strana 93

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 130
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 92
Troubleshooting & Error Messages
System will not talk
across VMEbus.
The VMEbus backplane
may not be jumpered
correctly.
More than 1 master may
be set to provide Slot-0
functions.
The EPC-7 may have bent
pins.
VMEbus interface failure.
See the section Installing the VXIbus
Backplane Jumpers, on page 7.
Make sure that only 1 system is
configured as the Slot-0 controller
and that it is the left-most system in
the chassis.
Remove the EPC-7 and verify that
no pins are bent. Then reinsert the
EPC-7.
Power off, then back on. Verify that
the results of the power-on self test
indicate VMEbus interface and
VXIbus interface report “ok.”
99
Page 83
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Zobrazit stránku 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 129 130

Komentáře k této Příručce

Žádné komentáře